Key Features
✅ Complete Electrical Protection
Protects appliances against Over Voltage, Under Voltage and Over Current conditions. Ideal for homes, offices, industries, commercial buildings, shops, pumps, motors, air conditioners and sensitive electronic equipment.
✅ Fully Adjustable Protection Settings
User programmable voltage and current limits with adjustable recovery values, trip delay and power-on delay for customized protection according to application requirements.
✅ Large LED Digital Display
Bright dual-color LED display continuously shows real-time voltage and load current with easy-to-read status indicators.
✅ Automatic Recovery
Automatically reconnects power after voltage returns within the safe operating range. Recovery delay prevents repeated switching during unstable power conditions.
✅ Heavy Duty 63A Capacity
Supports loads up to 63 Amps for single-phase electrical systems. DIN Rail mounting design makes installation simple inside distribution boards.
Product Description
Protect your valuable electrical equipment with the LEYDEN LE-VAP 63A Adjustable Voltage & Current Protection Device. Designed for residential, commercial and industrial applications, this intelligent protection relay continuously monitors incoming voltage and load current.
Whenever abnormal voltage or overload conditions occur, the device disconnects the power supply automatically to protect connected appliances. Once power returns to safe operating conditions, the relay reconnects automatically after the preset recovery delay.
The LE-VAP offers complete flexibility with programmable over-voltage, under-voltage, over-current, trip delay, recovery delay and power-on delay settings. Its bright LED display provides instant monitoring of voltage and current while advanced protection logic helps increase appliance life and reduces maintenance costs.
Suitable for:
- Homes
- Offices
- Commercial Buildings
- Factories
- Water Pumps
- Air Conditioners
- Refrigerators
- Deep Freezers
- Medical Equipment
- CNC Machines
- Industrial Panels
- Sensitive Electronic Equipment
Technical Specifications
Specification Details Brand LEYDEN Model LE-VAP Rated Voltage 220VAC Operating Voltage 80-300VAC Frequency 50/60Hz Rated Current 63A Installation DIN Rail Display LED Digital Display Protection Over Voltage, Under Voltage, Over Current Maximum Voltage 350VAC Voltage Accuracy <1% Operating Temperature -25°C to +50°C Storage Temperature -25°C to +55°C Humidity ≤50% RH (40°C, Non-condensing) Altitude ≤2000m Adjustable Parameters
Parameter Range Default Power ON Delay 1-999 Seconds 5 Seconds Recovery Delay 1-999 Seconds 30 Seconds Over Voltage 130-300V 270V Over Voltage Recovery 125-295V 265V Under Voltage 80-210V 170V Under Voltage Recovery 85-215V 175V Voltage Trip Delay 0.1-10 Seconds 0.5 Seconds Voltage Calibration ±10% 0 Over Current 1-63A 63A Current Trip Delay 0.1-10 Seconds 1 Second Continuous Over Current Count 0-20 Times OFF Current Calibration ±10% 0 Frequency Calibration ±2.5Hz 0 Display Mode Standard / Manual / Automatic Standard Automatic Reset ON / OFF ON Action Mode ON / OFF ON Energy Saving Standard / Energy Saving / Screen OFF Standard Password Lock 000-999 112 Package Contents
- 1 × LEYDEN LE-VAP 63A Protection Device
- 1 × User Manual
Installation Instructions
Before Installation
- Disconnect the main power supply completely.
- Ensure installation is performed by a qualified electrician.
- Verify supply voltage is 220-240VAC single phase.
- Use recommended wire size suitable for 63A load.
- Install inside a proper electrical distribution board.
Wiring
INPUT (Top Terminals)
- N → Neutral Supply
- L → Live Supply
OUTPUT (Bottom Terminals)
- N → Neutral to Load
- L → Live to Load
Always tighten all terminal screws securely.
Initial Setup
After installation:
- Switch ON the main supply.
- The display performs a self-test.
- Wait for the Power-On Delay countdown.
- Output turns ON automatically.
- Verify voltage and current display.
- Adjust parameters if required.
Programming Instructions
Enter Setting Mode
Press and hold SET for approximately 3 seconds.
Navigation
- SET → Next Parameter
- ▲ Increase Value
- ▼ Decrease Value
- Power Button → Exit
Parameter List
P1
Power ON Delay
Range:
1–999 SecondsP2
Recovery Delay
Range:
1–999 SecondsP3
Over Voltage Protection
Range:
130–300VP4
Over Voltage Recovery
Range:
125–295VP5
Under Voltage Protection
Range:
80–210VP6
Under Voltage Recovery
Range:
85–215VP7
Voltage Trip Delay
Range:
0.1–10 SecondsP8
Voltage Calibration
Factory adjustment.
Changing is generally not recommended unless verified with a calibrated meter.P9
Over Current Protection
Range:
1–63AP10
Current Trip Delay
Range:
0.1–10 SecondsP11
Continuous Over Current Count
0–20 trips
OFF disables counting.
P12
Current Calibration
Factory calibration.
Adjustment should only be performed using calibrated test equipment.P13
Frequency Calibration
Factory setting.
Normally leave unchanged.
P14
Display Mode
1 Standard
2 Manual Switch
3 Automatic Switch
P15
Automatic Reset
ON
Automatic Recovery
OFF
Manual Recovery
P16
Protection Action
ON
Protection Enabled
OFF
Knife (Bypass) Mode
P17
Energy Saving
1 Standard
2 Energy Saving
3 Screen OFF
P18
Password Lock
Default Password:
112
Changing the password restricts parameter modification.
Recommended Settings (Residential)
Over Voltage:
270VUnder Voltage:
170VRecovery Delay:
30 SecondsPower ON Delay:
5 SecondsCurrent Limit:
63AVoltage Trip Delay:
0.5 SecondsCurrent Trip Delay:
1 SecondSafety Instructions
- Installation must be performed only by a qualified electrician.
- Disconnect the power supply before wiring or maintenance.
- Use only 220–240VAC single-phase supply.
- Ensure all wiring complies with local electrical regulations.
- Tighten all terminal screws securely to avoid overheating.
- Use copper conductors of appropriate size.
- Do not exceed the rated current of 63A.
- Do not install in wet, corrosive, or explosive environments.
- Keep away from excessive moisture and direct water exposure.
- Ensure adequate ventilation inside the electrical panel.
- Never bypass or modify the protection circuitry.
- Inspect wiring periodically for loose connections.
- Replace damaged wiring immediately.
- Keep out of reach of children.
Maintenance
- Check terminal tightness every 6–12 months.
- Clean using a dry cloth only.
- Never use solvents or water.
- Inspect for signs of overheating or discoloration.
- Disconnect power before servicing.
Troubleshooting
Problem Possible Cause Solution Display OFF No input supply Check mains power Output not turning ON Delay timer active Wait until countdown finishes Over Voltage Trip Supply voltage too high Check mains voltage Under Voltage Trip Supply voltage too low Restore proper voltage Over Current Trip Load exceeds limit Reduce load or increase setting (within safe limits) Frequent Tripping Loose wiring or unstable supply Check all connections and incoming supply Warranty Terms
Warranty Period: 12 Months from the date of purchase.
Warranty Covers
- Manufacturing defects
- Internal electronic component failure under normal operating conditions
Warranty Does Not Cover
- Incorrect wiring
- Reverse polarity connections
- Burn damage due to loose terminals
- Overloading beyond 63A
- Short circuit damage
- Physical damage
- Water or moisture damage
- Fire damage
- Lightning or natural disasters
- Unauthorized repairs or modifications
- Damage caused by improper installation
- Broken housing, display, or terminals due to mishandling
Warranty Conditions
- Original purchase invoice is required.
- Product must not be opened or modified.
- Warranty is limited to repair or replacement of the product.
- The manufacturer is not liable for indirect damage to connected equipment.
- Stock: In Stock
- Model: LE-VAP 63A
- Weight: 0.20kg
- Dimensions: 20.00cm x 12.00cm x 7.00cm
- SKU: LE-VAP 63A